Is A Toilet Lift Right For You? A Screening Tool for Toilet Lifts

Choosing the correct assistive devices is very difficult. Occupational Therapists are often called upon to choose the right tools to help someone with their activities of daily living. Dignity Lifts developed this tool to help OTs figure out if a toilet lift is the best way to meet their patients' toileting needs. With this screening tool, Occupational Therapists can survey their patients and determine if a toilet lift is right for them.

You can download the .pdf file of this screening tool by clicking here.

Β 

Occupational Therapy Screening Tool

Toilet Transfer &
Toilet Lift Screener

This screener helps an OT decide, in about 15 minutes, whether a powered toilet lift is the right fit and level of support for a client.

Part Question it answers Format Time
A. Readiness profile What support will make a powered toilet lift work for this person? Scaled 2/1/0 per item; 0–10 points 2 min
B. Performance measures How impaired is sit-to-stand and toilet transfer, using validated tests? Timed/observed tests with published cut-offs; 0–13 points 5 min
C. Toileting need score How much does the lift address this person's actual toileting problems? Points, 0–17 (B + C = Need score, 0–30) 5 min
D. Environment & equipment fit Will a specific lift model fit the person and the bathroom? Checklist 3–5 min

Score Parts B and C from observation wherever possible; use client or caregiver report only when observation isn't feasible, and mark which you used. This is a clinical screening aid, not a validated instrument β€” the final recommendation rests on OT judgment.

Client information

Client name / ID Age / Sex (needed for chair-stand norms)
Height / Weight (lb) Primary diagnosis / relevant conditions
Setting (home, ALF, SNF, inpatient rehab) Lives alone / caregiver available (hours/day)
Precautions (hip, spinal, sternal, weight-bearing) Assessed by / date
Source of information Observed Client report Caregiver report

Part A β€” Readiness profile 0–10 points

Rate each item 2, 1 or 0. Most readiness gaps are solved by a caregiver operating the controls, the lift's armrests, or a brief consult with Dignity Lifts.

# Readiness area 2 β€” Ready 1 β€” Ready with support 0 β€” Plan needed Score
A1 Standing and weight bearing Stands β‰₯30 s with or without a mobility aid Stands with contact guard or one-person assist Not currently bearing weight
A2 Sitting balance on the toilet Steady without support Steady using armrests or side support Leans or slides even with support
A3 Operating the controls Client operates independently Caregiver operates, or client needs cueing No one available to operate yet
A4 Medical precautions (hip, spinal, sternal) None Present but compatible, or cleared by surgical team Clearance still pending
A5 Blood pressure on standing No dizziness on rising Occasional, managed (slow lift helps) Unmanaged orthostatic symptoms
Part A total / 10
8–10 ReadyProceed to recommendation.
5–7 Ready with supportProceed; build caregiver training and set-up into the plan.
0–4 Plan neededLift still in consideration? Book a free Dignity Lifts consultation to discuss questions you have.

Part B β€” Performance measures 0–13 points

Stand beside the client for every test.

B1. Sit-to-stand strength (choose one test; 0–4 points)

Option 1 β€” CDC STEADI 30-Second Chair Stand. Straight-back chair without arms, 17" seat, against a wall. Arms crossed at the chest. Count full stands in 30 seconds. If the client must use their arms, stop and record 0.

Option 2 β€” Five Times Sit-to-Stand (5xSTS). Same chair setup; time five full stands as fast as possible without arms. In community-dwelling older adults, β‰₯12 seconds flags the need for further fall assessment and >15 seconds is associated with recurrent falls.

Age Men: below average if fewer than Women: below average if fewer than
60–64 14 12
65–69 12 11
70–74 12 10
75–79 11 10
80–84 10 9
85–89 8 8
90–94 7 4
Result Points
30s CST average or above, or 5xSTS <12 s 0
5xSTS 12–15 s 1
30s CST below average for age/sex, or 5xSTS >15 s 2
Unable to stand without using arms (30s CST = 0, or 5xSTS not completed) 4
Test used / raw result: ______________________B1 score

B2. Toilet transfer β€” CMS Section GG item GG0170F (0–4 points)

Observe the client getting on and off a toilet or commode and rate with the standard 6-point GG scale. Using GG keeps this screen consistent with Medicare post-acute documentation (IRF-PAI, MDS, OASIS).

GG code Level of help Points
06 Independent 0
05 Setup or clean-up assistance only 1
04 Supervision or touching (contact guard) assistance 3
03 Partial/moderate assistance β€” helper does less than half the effort 4
02 Substantial/maximal assistance β€” helper does more than half 3
01 Dependent 3 β€” plan caregiver-operated set-up
B2 score

B3. Fall risk β€” CDC STEADI three key questions (0–5 points)

Question Yes = 1 point
Has the client fallen in the past year? (If yes: how many times? Injured?)
Does the client feel unsteady when standing or walking?
Does the client worry about falling?
Any fall, near-fall, or "getting stuck" on the toilet or in the bathroom in the past 12 months (+2 points)

A "Yes" to any of the three STEADI questions means the client screens at risk for falls and should receive a full STEADI multifactorial assessment, separate from the toilet lift decision.

B3 score Β Β Β Β  Part B total / 13

Part C β€” Toileting need score 0–17 points

These items capture what a toilet lift specifically solves: an effortful or unsafe rise, an uncontrolled descent, frequent trips, variable performance, and a seat height that is wrong for elimination. Score from observation in the client's own bathroom when possible.

# Finding Points Score
C1 Rising strategy. Rises in one smooth attempt = 0 Β· Multiple attempts, rocking or momentum = 2 Β· Pulls on fixtures not built to bear weight (sink, towel bar, toilet-roll holder, door handle) = 3 0 / 2 / 3
C2 Lowering control. Controlled descent = 0 Β· Drops or "plops" the last few inches = 2 0 / 2
C3 Toileting frequency. Under 6 trips per 24 h = 0 Β· 6–8 = 1 Β· More than 8, or 2+ night voids = 2 Β· Urgency or urge incontinence that causes rushing = 3 0–3
C4 Variable performance. Ability fluctuates with fatigue, time of day, medication cycles or flares (e.g., Parkinson's on/off, MS, COPD/CHF, arthritis, recent hospitalization) 2
C5 Seat height mismatch. On a raised seat or comfort-height toilet: feet don't rest flat, legs or feet go numb, or straining/constipation the client links to the seat. Common in clients under about 5'2" 2
C6 Caregiver burden and client goal. Caregiver physically helps the client rise = 2 Β· Client states privacy or independence in toileting as a goal = +1 0–3
C7 Simpler supports tried and insufficient. Grab bars, toilet safety frame or raised seat are in place and used correctly, but the rise is still difficult or unsafe 2
Part C total / 17
Need score Β Part B + Part C
Higher means a toilet lift addresses more of the client's problems.
/ 30

Part D β€” Environment and equipment fit

Measure before recommending a model. A lift that doesn't fit the room, the toilet or the client's body will be abandoned.

Toilet bowl height, floor to rim without seat (in)
Clear width at the toilet, wall-to-wall or wall-to-fixture (in)
Clear floor space in front of the toilet for standing and turning (in)
GFCI outlet within cord reach? (needed for plug-in models) Yes No
Existing grab bars / safety frame β€” would they need removing?
Client's hip width seated (in) vs. lift's inside handle width
From the lift's top position, can the client complete the stand, manage clothing and step or pivot to their mobility aid? Yes No
Who will clean, charge and maintain the lift?
Home vs. facility (shared use, room-to-room moves)

Model matching

Model Capacity Lift Power Fit notes Best for
DL2 Deluxe 300 lb 14" Rechargeable battery Fits most toilets and bathrooms; 19.5" width between arms Most home clients within capacity. Most popular.
WL2 Bidet 300 lb 14" Plugs into GFCI outlet Fits most toilets and bathrooms; 19.5" width between arms Complete hygiene for clients unable to clean themselves. Front and rear wash; air dry.
XL1 Extra Large 650 lb 9" Plugs into GFCI outlet 16–18" bowls; 30" overall width; removable arms Clients over 300 lb with a wide enough space
BL1 Basic 300 lb 9" Plugs into GFCI outlet 16–18" bowls; 23 7/8" overall width; 20" between handles Affordable option
HL1 Helper 250 lb 9" Rechargeable battery 17" of hip room BMAT level 2. Hoyer alternative.
CL1 Commercial 350 lb 11" Rechargeable battery Lockable wheels; moves between rooms Facilities and shared use
Selected model: ____________________ Β Β  Reason: ______________________________________________

Interpretation

Use the Need score (B + C) to set the strength of the recommendation, and the Readiness profile (A) to plan the set-up. These bands guide clinical reasoning; they are not validated cut-offs.

Need score Recommendation
14–30 Toilet lift strongly recommended. Recommend the matched model; train client and caregiver; follow up within 2 weeks.
6–13 Toilet lift recommended. Especially when C4 (variable performance), C5 (seat height mismatch) or C6 (caregiver assists) is scored. Grab bars can be added alongside the lift.
0–5 Toilet lift worth considering proactively for clients with a progressive condition, a recent hospitalization or fall, or a stated wish to stay independent at home; otherwise re-screen if function changes.
Act the same day at any score: pulling up on a sink, towel bar or door handle (C1 = 3), or any toileting fall.

Alternatives considered and documentation

Record what was considered so the recommendation reads as the least restrictive option that works.

  • Bilateral grab bars or fold-down rails
  • Toilet safety frame / toilet surround
  • Raised toilet seat or comfort-height toilet (note C5 trade-offs)
  • Footstool for elimination posture
  • Bedside or over-toilet commode
  • Strength, balance and transfer training (PT/OT)
  • Caregiver training in assisted transfers
  • Mechanical or sit-to-stand patient lift
Suggested documentation line: Client scored __/30 on the toilet lift screen (Part B __/13, Part C __/17), with a readiness profile of __/10, and demonstrated [GG0170F level] toilet transfers with [key observation]. A [model] toilet lift is recommended to [goal, e.g., restore independent toileting and reduce fall risk during sit-to-stand].
Readiness 0–4, or the right model is unclear?
Book a free Dignity Lifts video consultation β€” our team can add input to the toileting plan.
dignitylifts.com/pages/free-online-consultation

Sources

Β 

Β 

You can download the .pdf file of this screening tool by clicking here.

See Dignity Lifts's complete catalog of toilet lifts and assistive devices. Click here.

Close (esc)

Learn More About Toilet Lifts

Sign up now.

Search

Your cart is currently empty.
Shop now